Ruijie RG-S6510-4C 4 Slot Modüler Veri Merkezi Switch

ModelRG-S6510-4C

Ruijie RG-S6510-4C bir yönetilebilir switch'tir. Öne çıkan özellikleri: 96 x 25ge ports and 8 x 100ge ports, 32 x 100ge ports, housed in a 2 ru enclosure for flexible networking, cross-device link aggregation (de-stacking/m-lag/vsu), device-level redundancy, flexible networking, and high reliability, vxlan tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling, lossless ethernet, ensuring zero packet loss during rdma e2e communication.

PoE
PoE yok
Fiyat ve stok bilgisi alınAynı gün dönüş

Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.

Distribütör garantili
81 ile sevkiyat
Teknik destek
  • 96 x 25GE ports and 8 x 100GE ports, 32 x 100GE ports, housed in a 2 RU enclosure for flexible networking
  • Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
  • VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient

Teknik özellikler

Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.

Donanım Özellikleri 14 satır
Dimensions; (W × D × H)442 mm x 520 mm x 86 mm (17.40 in. x 20.47 in. x 3.39 in.)
Kabin Yüksekliği2 RU
Cihaz Ağırlığı14 kg (30.86 lbs., a chassis with two power modules and three fan modules)
Anahtarlama Kapasitesi6.4 Tbps
Paket İletim Hızı2030 Mpps
Yönetim Portu1 x RJ45 console port; 1 x RJ45 MGMT port
USB Portu1 x USB 2.0 port (Type A connector)
Modül Yuvası4 x expansion module slots; 2 x power module slots; 3 x fan module slots
Güç TüketimiMaximum power consumption: 600 W; Typical power consumption: 455 W; Static power consumption: 202 W
Güç GirişiRG-PA800I-F (AC input):; Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 10 A to 5 A (100 V AC to 240 V AC); Power port type: C14; RG-PA800I-F (HVDC input):; Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 310 V DC; Rated input current: 5 A; RG-PD800I-F (DC input):; Rated input voltage: –48 V DC; Maximum input voltage: –36 V DC to –72 V DC; Rated
SıcaklıkOperating temperature: 0°C to 40°C (32°F to 104°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 2000 m (6561.68 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.
NemOperating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing)
RakımOperating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.)
SoğutmaAir cooling, front-to-rear airflow (port-side intake)
Yazılım Özellikleri 13 satır
Layer 2 ProtocolsIEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and selective QinQ), GVRP
Layer 3 Protocols (IPv4)BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, Any-RP
IPv6 Basic ProtocolsNeighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS
IPv6 FeaturesStatic routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, manual tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel
Data Center FeaturesVXLAN routing and VXLAN bridging; EVPN VXLAN; IPv6 VXLAN over IPv4; PFC, ECN, and other data center features; RDMA; M-LAG; OpenFlow 1.3
VisualizationgRPC; sFLOW sampling; INT
QoSMapping of IEEE 802.1p, DSCP, and ToS priorities; ACL-based traffic classification; Priority marking/remarking; Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR; Congestion avoidance mechanisms such as WRED and tail discarding
SanallaştırmaVirtual Switching Unit
Buffer ManagementBuffer status monitoring and management, and identification of burst traffic
HA DesignGR for RIP/OSPF/BGP, BFD, REUP dual-link fast switching and RLDP unidirectional link detection, 1+1 power redundancy, and fan redundancy, and hot swapping for all line cards and power supply modules
Security FeaturesNetwork Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, gateway ARP spoofing preve
Yönetim ModuSNMP v1/v2c/v3, Netconf, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN, Telemetry, ZTP, Python, fan and power supply alarm, and temperature alarm
Other ProtocolsDHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog
Temel Özellikler 3 satır
Dimensions(W × D × H)442 mm x 520 mm x 86 mm (17.40 in. x 20.47 in. x 3.39 in.)
Çalışma Sıcaklığı0°C to 40°C (32°F to 104°F)
Çalışma Nemi10% RH to 90% RH (non-condensing)

Genel bakış

Ruijie RG-S6510-4C kullanım alanları ve özellikleri.

M-LAG/VSU/de-stacking for higher availability, PFC/ECN-based lossless RDMA network with high performance

Data Center 100GE Access Switch RG-S6510-4C

100GE high-density modular access switch with 10G/25G/100GE downlink ports 96 x 25GE ports and 8 x 100GE ports, 32 x 100GE ports, housed in a 2 RU enclosure for adaptation to different scenarios

Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability

De-stacking

M-LAG

VSU

De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.

M-LAG technology implements load sharing between links and improves link reliability. The independent control plane supports independent device upgrade, realizing service upgrade within seconds and consistent user experience.

VSU technology can virtualize multiple physical devices into one logical device, simplifying network configuration and architecture, eliminating loops, and improving reliability.

VXLAN Tunneling Technology, Achieving Unlimited Data Transmission and Flexible Resource Allocation and Scheduling

VXLAN technology creates virtual tunnels on an IP network by building a virtual Layer 2 network, implementing cross-region and cross-DC data migration, and flexible resource allocation and scheduling. The switch supports EVPN VXLAN to enhance the number of tenants, meeting requirements of identification and isolation between different networks on a large scale.

PFC- and ECN-based Lossless Ethernet with High Throughput and Low Latency in RDMA Scenarios

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden and effectively solves the network latency problem. PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

Nerelerde kullanılır?

Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.

Kurulum ve uyumluluk

Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.

Dokümanlar

Veri sayfası ve kullanım kılavuzları.

Sık sorulanlar

RG-S6510-4C hakkında kısa yanıtlar.

RG-S6510-4C fiyatı ne kadar?
RG-S6510-4C için fiyat; adet, proje kapsamı ve güncel kura göre değiştiğinden teklif usulüyle verilir. Ürünü teklif listenize ekleyerek veya telefon/WhatsApp hattımızdan ulaşarak aynı iş günü içinde fiyat ve stok bilgisi alabilirsiniz.

Hızlı teklif

Formu doldurun, RG-S6510-4C için fiyat ve teslim süresini iletelim.

Benzer ürünler

Yönetilebilir Switch

Tümü
Aynı seri

Ruijie RG-S6510