Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
RG-S6990-128QC2XSRuijie RG-S6990-128QC2XS, 28 portlu gigabit bir yönetilebilir switch'tir.
- Port hızı
- Gigabit
- PoE
- PoE yok
- Port sayısı
- 28 port
- High-density 400GE switch with 128 x 100GE/200GE/400GE QSFP112 ports housed in a 4-RU enclosure
- Eliminating packet loss during E2E communication through RDMA, building high-performance and low-latency data center networks
- Hardware-level redundancy, ensuring service continuity and preventing network downtime
- Nanosecond-level hardware failover, mitigating the impact of network faults on services and securing network stability
- AI-powered intelligent O&M, making management easy and efficient
Genel bakış
Ruijie RG-S6990-128QC2XS özellikleri ve kullanım alanları.
128 x 400GE ports and 2 x 10GE ports, RDLB and GDLB of the AI-Fabric solution to improve the bandwidth and shorten the AI training time in AIGC intelligent computing scenarios
RG-S6990-128QC2XS – 128-Port 400GE Data Center Fixed Switch
The high-speed and high-density core switch provides 128 x 400GE ports housed in a 4-RU enclosure, delivering scalable, high-performance, and high-bandwidth services for large-scale DCI networks.
Ports
Dimensions
Eliminating Packet Loss During E2E Communication Through RDMA, Building High-Performance and Low-Latency Data Center Networks
PFC and ECN are leveraged to implement intelligent data exchange and eliminate packet loss. With the RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU load and addresses network latency issues, ensuring lossless transmission of data. In addition, Remote Dynamic Load Balancing (RDLB) and Global Dynamic Load Balancing (GDLB) of the AI-Fabric solution solve the ECMP conflict caused by flow-based load balancing, improving the bandwidth and shortening the AI training time in AIGC intelligent computing scenarios.
Hardware-Level Redundancy, Ensuring Service Continuity and Preventing Network Downtime
Hot-Swappable Redundant Power Modules
Hot-Swappable Redundant Fan Modules
The switch supports 2+2 power redundancy, enables failover in seconds, and ensures network connectivity during power replacement. This provides dual protection for links.
The switch supports 4+1 fan redundancy with intelligent speed adjustment and efficient heat dissipation for building low-carbon data centers.
AI-Powered Intelligent O&M Making Management Easy and Efficient
The switch offers AI-powered automatic ECN tuning, real-time telemetry of key RoCE network metrics, visualization of endpoint status and RoCE services, along with congestion and packet loss analytics.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Dimensions; (W x D x H) | 446 mm x 800 mm x 173.6 mm (17.56 in. x 31.5 in. x 6.84 in.) |
|---|---|
| Kabin Yüksekliği | 4 RU |
| Cihaz Ağırlığı | 37.6 kg (82.89 lbs., empty chassis); 45 kg (99.21 lbs., a chassis with four power modules and five fan modules) |
| Anahtarlama Kapasitesi | 102.4 Tbps |
| Paket İletim Hızı | 21000 Mpps |
| Servis Portu | 128 x 100G/200G/400G QSFP112 ports; 2 x GE/10GE SFP+ ports |
| Yönetim Portu | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| USB Portu | 1 x USB 2.0 port (Type A connector) |
| Modül Yuvası | 4 x power module slots; 5 x fan module slots |
| Güç Tüketimi | Maximum power consumption: 3160 W; Typical power consumption: 2432 W; Static power consumption: 433 W |
| Güç Girişi | RG-PA1600II-F (AC input):; Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 12 A (100 V AC to 127 V AC); 9.5 A (200 V AC to 240 V AC); Power port type: C14; RG-PA1600II-F (HVDC input):; Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 300 V DC; Rated input current: 9.5 A |
| Sıcaklık | Operating temperature: 0°C to 40°C (32°F to 104°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 1,800 m (5,905.51 ft.) to 5,000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft) increase in elevation. |
| Nem | Operating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing) |
| Rakım | Operating altitude ≤ 5,000 m (16,404.20 ft.); Storage altitude ≤ 5,000 m (16,404.20 ft.) |
| Soğutma | Air cooling, front-to-rear airflow (port-side intake) |
| Layer 2 protocols | IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) |
|---|---|
| Layer 3 protocols (IPv4) | BGP4, OSPFv2, RIPv1, RIPv2, LPM Routing, Policy-based Routing, Route-policy, ECMP, WCMP, VRRP |
| Basic IPv6 protocols | Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS |
| IPv6 features | Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+ |
| Data center features | VXLAN, BGP-EVPN; RDMA; PFC, ECN; PFC deadlock prevention; AI ECN; ECN overlay; Global loading balancing, Remote Adaptive Load Balancing (RALB), Artificial Intelligence Scene Load Balancing (AILB), end-to-network load balancing (ENLB), source port-based load balancing (SPLB) |
| Visualization | Telemetry; sFlow; INT, MOD |
| QoS | IEEE 802.1p, DSCP, and ToS mapping; ACL-based traffic classification; Priority marking and re-marking; Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, SP+DRR; Congestion avoidance mechanisms such as WRED and tail discarding |
| High redundancy design | GR for RIP/OSPF/BGP, BFD, DLDP, REUP, Rapid Link Detection Protocol (RLDP), 2 + 2 power redundancy, fan redundancy, and hot swapping of line cards and power modules |
| Security features | Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), RADIUS/TACACS, IPv4/IPv6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet from specified IP addresses, broadcast packet suppression, and hierarchical user management; MLAG |
| Yönetim Modu | SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, temperature alarm |
| Other protocols | DHCP Client, DHCP Relay, DHCP Server, DNS Client, ARP Proxy, and Syslog |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-S6990-128QC2XS hakkında kısa yanıtlar.
RG-S6990-128QC2XS kaç portlu?
RG-S6990-128QC2XS fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-S6990-128QC2XS için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch kategorisinden
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch