Ruijie RG-S6510-48VS8CQ 48 Port 25G SFP28 8×100G QSFP28 Veri Merkezi Switch
RG-S6510-48VS8CQRuijie RG-S6510-48VS8CQ, 48 portlu bir yönetilebilir switch'tir.
- Port hızı
- 10G uplink
- PoE
- PoE yok
- Port sayısı
- 48 port
- 48 x 25GE SFP28 ports + 8 x 100GE QSFP28 ports, and 32 MB buffer, easily coping with burst traffic
- Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
- Multiple hardware-level protection, ensuring service consistency and network stability
- VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
- Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
- Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient
Genel bakış
Ruijie RG-S6510-48VS8CQ özellikleri ve kullanım alanları.
RDMA-capable high-density 25GE/100GE access switch for data center networks with low latency and no packet drop
25GE Data Center Access Switch RG-S6510-48VS8CQ
8 x 25GE SFP28 ports and 8 x 100GE QSFP28 ports, delivering line-rate forwarding capacity 32 MB buffer and advanced buffer scheduling mechanism, providing fast data processing and easily coping with burst traffic
Hardware-level Redundancy, Ensuring Service Continuity
Hot-swappable redundant power modules
Hot-swappable redundant fan modules
Power modules in 1+1 redundancy mode, and failover in seconds, providing nonstop services
Fan modules in 3+1 redundancy mode, intelligent fan speed adjustment, and highly-efficient heat dissipation, building low-carbon data centers
Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability
De-stacking
M-LAG
VSU
De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.
M-LAG technology implements load sharing between links and improves link reliability. The independent control plane supports independent device upgrade, realizing service upgrade within seconds and consistent user experience.
VSU technology can virtualize multiple physical devices into one logical device, simplifying network configuration and architecture, eliminating loops, and improving reliability.
VXLAN Tunneling Technology, Achieving Unlimited Data Transmission and Flexible Resource Allocation and Scheduling
VXLAN technology creates virtual tunnels on an IP network by building a virtual Layer 2 network, implementing cross-region and cross-DC data migration, and flexible resource allocation and scheduling. The switch supports EVPN VXLAN to enhance the number of tenants, meeting requirements of identification and isolation between different networks on a large scale.
PFC- and ECN-based Lossless Ethernet with High Throughput and Low Latency in RDMA Scenarios
With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden and effectively solves the network latency problem. PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission
Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient
The switch enabled with Telemetry/gRPC/sFlow/SPAN provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Boyutlar (G x D x Y) | 442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.) |
|---|---|
| Kabin Yüksekliği | 1 RU |
| Cihaz Ağırlığı | 5.6 kg (12.35 lbs., empty chassis); 8.2 kg (18.08 lbs., a chassis with two power modules and four fan modules) |
| Anahtarlama Kapasitesi | 4.0 Tbps |
| Paket İletim Hızı | 2000 Mpps |
| Servis Portu | 48 x 10G/25G SFP28 ports; 8 x 40G/100G QSFP28 ports |
| Yönetim Portu | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| USB Portu | 1 x USB 2.0 port (Type A connector) |
| Modül Yuvası | 2 x power module slots; 4 x fan module slots |
| Güç Tüketimi | Maximum power consumption: 300 W; Typical power consumption: 172 W; Static power consumption: 98 W |
| Güç Girişi | RG-PA550I-F (AC input):; Rated input voltage:; 100V AC to 240V AC, 50 Hz/60Hz; Maximum input voltage:; 90 V AC to140 V AC, 180 V to 264 V AC, 47 Hz to 63 Hz; Rated input current:; 7.2 A to3.5 A(100 V AC to 240 V AC); Power port type: C14; RG-PA550I-F (HVDC input):; Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 310 V DC; Rated current: 3.6 A; RG-PA550I-R (AC input):; 100 V AC to 240 V AC, 50 Hz/60 Hz; 90 V AC to140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; 7.2 A to 3.5 A(100 |
| Sıcaklık | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 1800 m (5905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
| Nem | Operating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing) |
| Rakım | Operating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.) |
| Soğutma | Air cooling, front-to-rear airflow (port-side intake): used with the RG-PA550I-F, RG-PD800I-F, and RG-PHD550I-F power modules; Air cooling, rear-to-front airflow (port-side exhaust): used with the RG-PA550I-R power module |
| Layer 2 Protocols | IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and Selective QinQ), GVRP |
|---|---|
| Layer 3 Protocols (IPv4) | BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/DM, MSDP, Any-RP |
| IPv6 Basic Protocols | Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS |
| IPv6 Features | Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, manual tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel |
| Data Center Features | VXLAN routing and VXLAN bridging; IPv6 VXLAN over IPv4 and EVPN VXLAN; PFC, ECN, and RDMA; M-LAG; OpenFlow 1.3 |
| Visualization | gRPC; sFLOW sampling; INT |
| QoS | Mapping of IEEE 802.1p, DSCP, and ToS priorities; ACL-based traffic classification; Priority marking/remarking; Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR; Congestion avoidance mechanisms such as WRED and tail discarding |
| Sanallaştırma | Virtual Switching Unit |
| Buffer Management | Buffer status monitoring and management, and identification of burst traffic |
| HA Design | GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules |
| Security Features | Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, ARP spoofing prevention, A |
| Yönetim Modu | SNMP v1/v2c/v3, Netconf, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, Python, fan and power alarm, and temperature alarm |
| Other Protocols | DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) |
|---|---|
| Çalışma Nemi | 10% RH to 90% RH (non-condensing) |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-S6510-48VS8CQ hakkında kısa yanıtlar.
RG-S6510-48VS8CQ kaç portlu?
RG-S6510-48VS8CQ fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-S6510-48VS8CQ için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch kategorisinden
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6510 serisi