Distribütör garantili ürünFaturalı satış · Türkiye geneli sevkiyatProjeye özel teklif

Ruijie RG-S6250-48XS8CQ 48 Port 10G SFP+ 8×100G QSFP28 Veri Merkezi Switch

ModelRG-S6250-48XS8CQ

Ruijie RG-S6250-48XS8CQ, 48 portlu bir yönetilebilir switch'tir.

Port hızı
10G uplink
PoE
PoE yok
Port sayısı
48 port
  • 48 x 1G/10G SFP+ ports and 8 x 40G/100G QSFP28 ports
  • Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
  • VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient
Fiyat ve stok bilgisi alınAynı iş günü dönüş

Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.

Distribütör garantili
Türkiye geneli sevkiyat
Kurulum ve teknik destek

Genel bakış

Ruijie RG-S6250-48XS8CQ özellikleri ve kullanım alanları.

M-LAG/VSU/de-stacking for higher availability, PFC/ECN-based lossless RDMA network with high performance

Data Center 10GE Access Switch RG-S6250-48XS8CQ

10GE high-density access switch with 10GE/100GE downlink ports and 100GE uplink ports backward compatible with 40GE for adaptation to different scenarios Large buffer and advanced buffer scheduling mechanism, providing fast data processing and easily coping with burst traffic

Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability

De-stacking

M-LAG

VSU

De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.

M-LAG technology implements load sharing between links and improves link reliability. The independent control plane supports independent device upgrade, realizing service upgrade within seconds and consistent user experience.

VSU technology can virtualize multiple physical devices into one logical device, simplifying network configuration and architecture, eliminating loops, and improving reliability.

PFC- and ECN-based Lossless Ethernet with High Throughput and Low Latency in RDMA Scenarios

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden and effectively solves the network latency problem. PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

Nerelerde kullanılır?

Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.

Kurulum ve uyumluluk

Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.

Teknik özellikler

Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.

Donanım Özellikleri
Boyutlar (G x D x Y)442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.)
Kabin Yüksekliği1 RU
Cihaz Ağırlığı5.6 kg (12.35 lbs., empty chassis); 8.2 kg (18.08 lbs., a chassis installed with two power modules and four fan modules)
Anahtarlama Kapasitesi2.56 Tbps
Paket İletim Hızı1920 Mpps
Servis Portu48 x 1G/10G SFP+ ports; 8 x 40G/100G QSFP28 ports
Yönetim Portu1 x RJ45 console port; 1 x RJ45 MGMT port
USB Portu1 x USB 2.0 port (Type A connector)
Modül Yuvası2 x power module slots; 4 x fan module slots
Güç TüketimiMaximum power consumption: 300 W; Typical power consumption: 165 W; Static power consumption: 98 W
Güç GirişiRG-PA550I-F (AC input):; Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 7.2 A to 3.5 A (100 V AC to 240 V AC); Power port type: C14; RG-PA550I-F (HVDC input):; Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 310 V DC; Rated current: 3.6 A; RG-PHD550I-F (AC input):; Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 10 A; RG-PHD550I-F (HVD
SıcaklıkOperating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.
NemOperating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing)
RakımOperating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.)
SoğutmaAir cooling, front-to-rear airflow (port-side intake)
Yazılım Özellikleri
Layer 2 protocolsIEEE802.3ae (10GBase), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (static link aggregation, LACP, M-LAG), IEEE802.1p, IEEE802.1Q,; IEEE802.1D (STP), STP root guard, and BPDU guard; IEEE802.1w(RSTP), IEEE802.1s(MSTP); IGMP Snooping v1/v2, MLD Snooping, Jumbo Frame(9Kbytes); IEEE 802.1ad (QinQ and selective QinQ), GVRP, Three modes (access, trunk, and hybrid), LLDP, static MAC address, MAC address filtering, MAC address quantity limit
Layer 3 protocols (IPv4)Static routing, BGP4, OSPFv2, IS-IS, RIPv1, RIPv2, MBGP, LPM routing, policy-based routing (PBR), route-policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, and Any-RP, BFD for BGP/IS-IS/OSPF/static routing, manual tunnel, GRE tunnel
Basic IPv6 protocolsNeighbor discovery, ICMPv6, path MTU discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, IS-ISv6, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS
IPv6 featuresStatic routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, IS-ISv6, IPv6 VRRP, MLDv1/v2, PIM-SMv6, manual tunnel, GRE tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel
Data center featuresVXLAN routing and VXLAN bridging; EVPN VXLAN; VXLAN mapping; IPv4 VXLAN over IPv4; IPv6 VXLAN over IPv4; IPv6 VXLAN over IPv6; VXLAN over IPv6; M-LAG; OpenFlow 1.3; RDMA, RoCEv2, PFC, and ECN
ProcessgRPC; sFlow sampling; IPFIX sampling
QoSIEEE 802.1p, ToS, and DSCP priority mapping; ACL traffic classifier, and priority tagging Mark/Remark; Various queue scheduling mechanisms such as SP (PQ), WRR, DRR, SP (PQ)+WRR, and SP (PQ)+DRR; Flexible queue scheduling algorithms based on ports or queues; Congestion avoidance mechanisms such as WRED and tail discarding; Ingress/egress port-based rate limiting and CAR
MPLSMPLS VPN
SanallaştırmaVirtual switching unit (VSU)
Buffer managementBuffer usage monitoring and traffic microburst detection
High availabilityGR for RIP/OSPF/BGP, BFD, DLDP, VRRP, VRRP load balancing/dual-active, BFD for VRRP, REUP, RLDP, 1+1 power redundancy and fan redundancy, and hot swappable line cards and power modules
Security featuresNetwork Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), DDoS/DoS attack defense, ICMP attack defense, unauthorized packet detection, data encryption, source IP spoofing defense, IP scanning attack defense, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL, port-based ACL, or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, Telnet login from specified IP addresses, uRPF, broadcast packet suppression, DHCP snooping, ARP s
Yönetim ModuSNMP v1/v2c/v3, Telnet, Console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, NETCONF, Python, fan and power alarm, temperature alarm, and configuration rollback
Other protocolsDHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP Relay, Proxy ARP, and Syslog
Temel Özellikler
Çalışma Sıcaklığı0°C to 45°C (32°F to 113°F)
Çalışma Nemi10% RH to 90% RH (non-condensing)

Dokümanlar

Veri sayfası ve kullanım kılavuzları.

Sık sorulanlar

RG-S6250-48XS8CQ hakkında kısa yanıtlar.

RG-S6250-48XS8CQ kaç portlu?
RG-S6250-48XS8CQ 48 porta sahiptir.
RG-S6250-48XS8CQ fiyatı ne kadar?
RG-S6250-48XS8CQ için fiyat; adet, proje kapsamı ve güncel kura göre değiştiğinden teklif usulüyle verilir. Ürünü teklif listenize ekleyerek veya telefon/WhatsApp hattımızdan ulaşarak aynı iş günü içinde fiyat ve stok bilgisi alabilirsiniz.

Hızlı teklif

Formu doldurun, RG-S6250-48XS8CQ için fiyat ve teslim süresini iletelim.

● Benzer ürünler

Yönetilebilir Switch kategorisinden

Tümünü gör →