Ruijie RG-S6250-48XS8CQ 48 Port 10G SFP+ 8×100G QSFP28 Veri Merkezi Switch
RG-S6250-48XS8CQRuijie RG-S6250-48XS8CQ, 48 portlu bir yönetilebilir switch'tir.
- Port hızı
- 10G uplink
- PoE
- PoE yok
- Port sayısı
- 48 port
- 48 x 1G/10G SFP+ ports and 8 x 40G/100G QSFP28 ports
- Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
- VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
- Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
- Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient
Genel bakış
Ruijie RG-S6250-48XS8CQ özellikleri ve kullanım alanları.
M-LAG/VSU/de-stacking for higher availability, PFC/ECN-based lossless RDMA network with high performance
Data Center 10GE Access Switch RG-S6250-48XS8CQ
10GE high-density access switch with 10GE/100GE downlink ports and 100GE uplink ports backward compatible with 40GE for adaptation to different scenarios Large buffer and advanced buffer scheduling mechanism, providing fast data processing and easily coping with burst traffic
Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability
De-stacking
M-LAG
VSU
De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.
M-LAG technology implements load sharing between links and improves link reliability. The independent control plane supports independent device upgrade, realizing service upgrade within seconds and consistent user experience.
VSU technology can virtualize multiple physical devices into one logical device, simplifying network configuration and architecture, eliminating loops, and improving reliability.
PFC- and ECN-based Lossless Ethernet with High Throughput and Low Latency in RDMA Scenarios
With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden and effectively solves the network latency problem. PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission
Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient
The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Boyutlar (G x D x Y) | 442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.) |
|---|---|
| Kabin Yüksekliği | 1 RU |
| Cihaz Ağırlığı | 5.6 kg (12.35 lbs., empty chassis); 8.2 kg (18.08 lbs., a chassis installed with two power modules and four fan modules) |
| Anahtarlama Kapasitesi | 2.56 Tbps |
| Paket İletim Hızı | 1920 Mpps |
| Servis Portu | 48 x 1G/10G SFP+ ports; 8 x 40G/100G QSFP28 ports |
| Yönetim Portu | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| USB Portu | 1 x USB 2.0 port (Type A connector) |
| Modül Yuvası | 2 x power module slots; 4 x fan module slots |
| Güç Tüketimi | Maximum power consumption: 300 W; Typical power consumption: 165 W; Static power consumption: 98 W |
| Güç Girişi | RG-PA550I-F (AC input):; Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 7.2 A to 3.5 A (100 V AC to 240 V AC); Power port type: C14; RG-PA550I-F (HVDC input):; Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 310 V DC; Rated current: 3.6 A; RG-PHD550I-F (AC input):; Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 10 A; RG-PHD550I-F (HVD |
| Sıcaklık | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
| Nem | Operating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing) |
| Rakım | Operating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.) |
| Soğutma | Air cooling, front-to-rear airflow (port-side intake) |
| Layer 2 protocols | IEEE802.3ae (10GBase), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (static link aggregation, LACP, M-LAG), IEEE802.1p, IEEE802.1Q,; IEEE802.1D (STP), STP root guard, and BPDU guard; IEEE802.1w(RSTP), IEEE802.1s(MSTP); IGMP Snooping v1/v2, MLD Snooping, Jumbo Frame(9Kbytes); IEEE 802.1ad (QinQ and selective QinQ), GVRP, Three modes (access, trunk, and hybrid), LLDP, static MAC address, MAC address filtering, MAC address quantity limit |
|---|---|
| Layer 3 protocols (IPv4) | Static routing, BGP4, OSPFv2, IS-IS, RIPv1, RIPv2, MBGP, LPM routing, policy-based routing (PBR), route-policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, and Any-RP, BFD for BGP/IS-IS/OSPF/static routing, manual tunnel, GRE tunnel |
| Basic IPv6 protocols | Neighbor discovery, ICMPv6, path MTU discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, IS-ISv6, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS |
| IPv6 features | Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, IS-ISv6, IPv6 VRRP, MLDv1/v2, PIM-SMv6, manual tunnel, GRE tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel |
| Data center features | VXLAN routing and VXLAN bridging; EVPN VXLAN; VXLAN mapping; IPv4 VXLAN over IPv4; IPv6 VXLAN over IPv4; IPv6 VXLAN over IPv6; VXLAN over IPv6; M-LAG; OpenFlow 1.3; RDMA, RoCEv2, PFC, and ECN |
| Process | gRPC; sFlow sampling; IPFIX sampling |
| QoS | IEEE 802.1p, ToS, and DSCP priority mapping; ACL traffic classifier, and priority tagging Mark/Remark; Various queue scheduling mechanisms such as SP (PQ), WRR, DRR, SP (PQ)+WRR, and SP (PQ)+DRR; Flexible queue scheduling algorithms based on ports or queues; Congestion avoidance mechanisms such as WRED and tail discarding; Ingress/egress port-based rate limiting and CAR |
| MPLS | MPLS VPN |
| Sanallaştırma | Virtual switching unit (VSU) |
| Buffer management | Buffer usage monitoring and traffic microburst detection |
| High availability | GR for RIP/OSPF/BGP, BFD, DLDP, VRRP, VRRP load balancing/dual-active, BFD for VRRP, REUP, RLDP, 1+1 power redundancy and fan redundancy, and hot swappable line cards and power modules |
| Security features | Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), DDoS/DoS attack defense, ICMP attack defense, unauthorized packet detection, data encryption, source IP spoofing defense, IP scanning attack defense, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL, port-based ACL, or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, Telnet login from specified IP addresses, uRPF, broadcast packet suppression, DHCP snooping, ARP s |
| Yönetim Modu | SNMP v1/v2c/v3, Telnet, Console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, NETCONF, Python, fan and power alarm, temperature alarm, and configuration rollback |
| Other protocols | DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP Relay, Proxy ARP, and Syslog |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) |
|---|---|
| Çalışma Nemi | 10% RH to 90% RH (non-condensing) |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-S6250-48XS8CQ hakkında kısa yanıtlar.
RG-S6250-48XS8CQ kaç portlu?
RG-S6250-48XS8CQ fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-S6250-48XS8CQ için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch kategorisinden
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch