Distribütör garantili ürünlerFaturalı satış · 81 ile sevkiyatAynı gün teklif

Ruijie RG-S6120-20XS4VS2QXS 20 Port 10G SFP+ 4×25G SFP28 2×40G QSFP+ L3 Yönetilebilir Switch

ModelRG-S6120-20XS4VS2QXS

Ruijie RG-S6120-20XS4VS2QXS, 20 portlu bir yönetilebilir switch'tir. VLAN, QoS ve port izleme gibi yönetim özellikleri sunar.

Port hızı
10G uplink
PoE
PoE yok
Port sayısı
20 port
Fiyat ve stok bilgisi alınAynı gün dönüş

Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.

Distribütör garantili
81 ile sevkiyat
Teknik destek
  • Rich port types, 20 x 1GE/2.5GE/10GE SFP+ ports , 4 x 10GE/25GE SFP28 ports , and 2 x 40GE QSFP+ ports for uplink
  • VSU virtualization, flexible networking and high performance
  • Hardware redundancy, guaranteed service continuity and network connectivity
  • Network security policies and real-time monitoring, delivering enhanced network robustness
  • Abundant QoS policies for flexible resource allocation, congestion is a thing of the past
  • Multiple management modes, simple and easy maintenance

Teknik özellikler

Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.

Donanım Özellikleri 14 satır
Sabit Servis Portları20 x 1GE/2.5GE/10GE SFP+ ports; 4 x 10GE/25GE SFP28 ports; 2 x 40GE QSFP+ ports (1 x 40GE port can be split into 4 x 10GE ports); Note: One switch provides a maximum of 32 x 10GE ports
Modül Yuvası2 x power module slots; 2 x fan module slots
Güç ModülüRG-PA150IB-F
Fan ModülüM1SFAN I-F (pre-installed 2)
Sabit Yönetim Portu1 x RJ45 console port; 1 x RJ45 MGMT port
USB1 x USB 2.0 port
Sistem Paket İletim Hızı678 Mpps
Sistem Anahtarlama Kapasitesi912 Gbps
İşlemci (CPU)Single-core CPU, with the clock speed of 1.25 GHz
Gerçek Zamanlı Saat (RTC)Destekleniyor
BootROM16 MB (storing boot software for 1+1 boot redundancy)
Flash Bellek1 GB (storing boot software for 1+1 boot redundancy)
Bellek1 GB, 32-bit width, 4-bit ECC
Switch Tampon Belleği4 MB
*2 means the system's switching capacity. 25 satır
Güç Kaynağı2 x pluggable power modules
Güç Modülü Yedekliliği1+1 redundancy
Güç GirişiRG-PA150IB-F(AC input):; Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz; Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; Maximum input current: 3 A; RG-PD150IB-F (DC input):; Rated input voltage: –48 V DC to –60 V DC; Maximum input voltage: –36 V DC to –75 V DC; Maximum input current: 5 A
Maks. Çıkış GücüRG-PA150IB-F: 150 W; RG-PD150IB-F: 150 W
Maks. Güç Tüketimi85 W
Cihaz Boyutları (G x D x Y)440 mm x 330 mm x 43.6 mm (17.3 in. x 12.99 in. x 1.72 in.)
Kabin Yüksekliği1 RU
Kutu Boyutları (G x D x Y)545 mm x 500 mm x 235 mm (21.46 in. x 19.69 in. x 9.25 in.)
Cihaz Ağırlığı4.6 kg (10.14 lbs, with two fan modules)
Kutulu Ağırlık5.70 kg (12.57 lbs)
SıcaklıkOperating temperature: 0°C to 50°C (32°F to 122°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At an altitude between 3,000 m (9,842.52 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum temperature decreases by 1°C (1.8°F).
NemOperating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing)
RakımStorage altitude: –500 m to 5,000 m (–1640.42 ft. to +16,404.20 ft.); Operating altitude: –500 m to 5,000 m (–1640.42 ft. to +16,404.20 ft.)
MTBF200,000 hours (about 22 years)
Fan2 x pluggable fan modules
Isı DağılımıFan cooling, front-to-rear airflow
Gürültü SeviyesiMaximum value: < 78 dB
Güç Modülü Sıcak TakasDestekleniyor
USB hot swappingDestekleniyor
Cable hot swappingDestekleniyor
Güç Kaynağı İzlemeMonitoring of power supply model and status; Power supply failure alarming
Fan İzlemeAutomatic speed adjustment; Fan failure alarming
Sıcaklık İzlemeTemperature monitoring, over-temperature alarming
ESD KorumasıESD contact/air discharge: 6 kV/8 kV; ESD susceptibility contact/air discharge: 8 kV/15 kV
Aşırı Gerilim KorumasıMGMT port: 4 kV; Service port: 6 kV; RG-PA150IB-F: common mode 6 kV, differential mode 6 kV
Sertifikalar ve Uyumluluk 3 satır
Güvenlik StandardıIEC 62368-1
EMC StandardıEN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11
RoHSEuropean RoHS Directive 2011/65/EU & Amendment(EU) 2015/863
Performans ve Kapasite 14 satır
Maks. VSU Üye Sayısı4
VSU bandwidth200 Gbps
Maximum number of SVIs1,000
Maks. MAC Adres Kaydı32,768
Maks. ARP Kaydı160,000
Maximum number of ND entries4,000
Maks. IPv4 Unicast Rota16,000 (shared with IPv6 routes)
Maks. IPv6 Unicast Rota8,000 (shared with IPv4 routes)
Maximum number of IPv4 multicast routes4,000
Maximum number of IPv6 multicast routes2,000
Maximum number of IGMP groups4,000
Maximum number of MLD groups2,000
Maximum number of VRF instances100
Maximum number of ACEsIn: 2,500 Out: 1,000
Functiion 9 satır
Ethernet AnahtarlamaJumbo frame (maximum length: 9,216 bytes); IEEE 802.1Q (supporting 4K VLANs); Maximum number of VLANs that can be created: 4,094; Voice VLAN; Super-VLAN and private VLAN; MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment; GVRP; Basic QinQ and selective QinQ; STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s); ERPS (G.8032); LACP (IEEE 802.3ad); LLDP/LLDP-MED; Non blocking
IP ServisleriStatic and dynamic ARP; DHCP server, DHCP client, DHCP relay, and DHCP snooping; DNS; DHCPv6 Client, DHCPv6 relay, and DHCPv6 snooping; Neighbor Discovery (ND) and ND snooping
IP YönlendirmeStatic routing; RIP and RIPng; OSPFv2 and OSPFv3; GR; IS-IS; BGP4 and BGP4+; BGP4 and MP-BGP; Equal and Weighted Cost Multi-Path (ECMP); IPv4/IPv6 VRF; IPv4/IPv6 PBR
MulticastIGMPv1/v2/v3 and IGMP proxy; IGMPv1/v2/v3 snooping; IGMP filtering and IGMP fast leave; PIM-DM, PIM-SM, and PIM-SSM; PIM-SSM for IPv4 and IPv6; MLDv1/v2; MLDv1/v2 snooping; MSDP; PIM-SMv6; Multicast source IP address check; Multicast source port check; Validity check of IGMP packets; Multicast querier
ACL ve QoSStandard IP ACLs (hardware ACLs based on IP addresses); Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers); Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type); Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range); Time-based ACLs; ACL80 and IPv6 ACL; Applying ACLs globally (hardware A
GüvenlikAAA; RADIUS and TACACS+; Filtering of invalid MAC addresses; Broadcast storm suppression; Hierarchical management of administrators and password protection; BPDU guard; RADIUS authentication and authorization; Port- and MAC address-based 802.1x authentication; IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication; Web authentication; Hypertext Transfer Protocol Secure (HTTPS); SSHv1 and SSHv2; ICMPv6; IPv6 addressing a
GüvenilirlikREUP; Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control; Data Link Detection Protocol (DLDP); IPv4 VRRP v2/v3 and IPv6 VRRP; BFD; GR for RIP, OSPF, BGP, and other routing protocols; Power modules in 1+1 redundancy mode; Hot swapping of power modules and fan modules
Cihaz SanallaştırmaVSU
Ağ Yönetimi ve BakımSPAN, RSPAN, and ERSPAN; sFlow; NTP, SNTP, and NTP for IPv6; FTP and TFTP; FTP/TFTP v6; SNMP v1/v2/v3; SNMP over IPv6; RMON (1, 2, 3, 9); Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groups; RMON used to implement Ethernet statistics, historical statistics, and alarm functions; NETCONF; Flow-based mirroring, and N:1 and 1:N port mirroring; CWMP; gRPC; OpenFlow Special 1.3; Flow table analysis defined
Temel Özellikler 4 satır
Sistem Anahtarlama Kapasitesi912 Gbps
Sistem Paket İletim Hızı678 Mpps
Çalışma Sıcaklığı0°C to 50°C (32°F to 122°F)
Warranty duration3 years

Genel bakış

Ruijie RG-S6120-20XS4VS2QXS kullanım alanları ve özellikleri.

A Red Dot Design Award winner. Recommended core or aggregation switch for small and medium-sized enterprise deployment.

Layer 3 All-Optical 10G Core & Aggregation Switch RG-S6120-20XS4VS2QXS

Recommended aggregation switch for large-sized networks, or core switch for small and medium-sized networks. With 20 x 1GE/2.5GE/10GE SFP+ ports and 4 x 10GE/25GE SFP28 ports, the switch provides flexible access capabilities. The 2 x 40GE QSFP+ uplink ports deliver high-speed uplink connectivity, fully satisfying the requirements of high-performance networks.

VSU Virtualization, Flexible Networking and High Performance

Millisecond Failover

High Scalability

Simplified Networking

The VSU connects to peripherals through an aggregate link, realizing service switching in milliseconds upon a failure.

VSU virtualization technology is supported to increase bandwidth through link aggregation, which greatly improves forwarding capabilities of the switch.

Multiple physical switches can be virtualized into one logical unit to simplify network configuration and architecture, eliminating loops, and improving reliability.

Hardware Redundancy, Guaranteed Service Continuity and Network Connectivity

Hot-Swappable Power Modules + Intelligent Fan Modules

Hardware-Level Boot Redundancy

Optical Port Fault Isolation

Power modules can be replaced without affecting device operation. Intelligent fan speed regulation is supported for efficient cooling, providing dual protection for the network.

Two Flash chips are used to store the system boot program for hardware-level boot redundancy, avoiding device failure caused by a failed Flash chip.

The innovative isolated chip design ensures that short-circuit current cannot reach the power supply chip directly. Failure of one optical module will not affect the normal operation of other optical ports, thus effectively ensuring service stability.

Network Security Policies and Real-Time Monitoring, Delivering Enhanced Network Robustness

CPP

NFPP

CPP protects the CPU from data attacks to ensure CPU stability under high usage, achieving significant improvement in the device's security performance.

NFPP protects CPU from high load damage to guarantee device management and operation, thus improving network security and stability.

Ruijie Unified Networking Central (RG-UNC) Visualized Management, Automated and Effortless Operations

RG-UNC, a unified visual management platform, supports real-time monitoring of key devices and links, fine-grained alarms, centralized configuration backup and recovery, network-wide management, plug-and-play, and rapid deployment, enhancing O&M efficiency.

RG-UNC Unified Networking Central – Simplified Management, Automated and Effortless Operations

Unified platform management, real-time monitoring of network status, comprehensive insight into the user experience chain, intelligent analysis and diagnosis, and comprehensive protection of the business experience. Supports end-to-end operation and maintenance of optical links, and makes optical networks visible, manageable, and controllable.

Nerelerde kullanılır?

Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.

Kurulum ve uyumluluk

Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.

Sık sorulanlar

RG-S6120-20XS4VS2QXS hakkında kısa yanıtlar.

RG-S6120-20XS4VS2QXS kaç portlu?
RG-S6120-20XS4VS2QXS 20 porta sahiptir.
RG-S6120-20XS4VS2QXS fiyatı ne kadar?
RG-S6120-20XS4VS2QXS için fiyat; adet, proje kapsamı ve güncel kura göre değiştiğinden teklif usulüyle verilir. Ürünü teklif listenize ekleyerek veya telefon/WhatsApp hattımızdan ulaşarak aynı iş günü içinde fiyat ve stok bilgisi alabilirsiniz.

Hızlı teklif

Formu doldurun, RG-S6120-20XS4VS2QXS için fiyat ve teslim süresini iletelim.

Benzer ürünler

Yönetilebilir Switch

Tümü