Ruijie RG-S5760C-48GT4XS-X 48 Port Gigabit 4×10G SFP+ L3 Yönetilebilir Switch
RG-S5760C-48GT4XS-XRuijie RG-S5760C-48GT4XS-X, 48 portlu gigabit bir yönetilebilir switch'tir. VLAN, QoS ve port izleme gibi yönetim özellikleri sunar.
- Port hızı
- Gigabit
- PoE
- PoE yok
- Port sayısı
- 48 port
- Rich port types, 48 x 10/100/1000BAST-T ports for access, and 4 x 1GE/10GE SFP+ ports for uplink
- Hardware redundancy, guaranteed service continuity and network connectivity
- VSU virtualization, flexible networking and high performance
- Layer 3 routing control, adaptive to multiple services, efficient and guaranteed data transmission
- Network security policies, real-time monitoring, CPP and NFPP, delivering enhanced network robustness
- SNMP, RMON, Syslog, USB log backup features, CLI, Eweb, telnet and other management modes, simplified and easy network maintenance
Genel bakış
Ruijie RG-S5760C-48GT4XS-X özellikleri ve kullanım alanları.
Aggregation switch for large-sized networks, or core switch for small and medium-sized networks
Layer 3 GE Core & Aggregation Switch S5760C-48GT4XS-X
Aggregation switch for small and medium-sized campus networks, with 4 x 1GE/10GE SFP+ uplink ports for high-speed data transmission; 48 x 10/100/1000BAST-T ports, providing high-speed network experience for short-distance services. Core switch for small and medium-sized enterprise networks, with high scalability, efficiency, and manageability, and device-level and link-level reliabilities for stable connectivity.
Hardware Redundancy, Guaranteed Service Continuity and Network Connectivity
Hardware-level Boot Redundancy
Hot-Swappable Power Modules
Two Flash chips are used to store the system boot program for hardware-level boot redundancy, avoiding device failure caused by a failed Flash chip.
Power module failover can be achieved in a few seconds. Power modules can be replaced without affecting device operation, providing dual protection for the network.
VSU Virtualization, Flexible Networking and High Performance
Millisecond Failover
High Scalability
Simplified Networking
The VSU connects to peripherals through an aggregate link, realizing service switching in milliseconds upon a failure.
VSU virtualization technology is supported to increase bandwidth through link aggregation, which greatly improves forwarding capabilities of the switch.
Multiple physical switches can be virtualized into one logical unit to simplify network configuration and architecture, eliminating loops, and improving reliability.
Layer 3 Routing Control, Adaptive to Multiple Services, Efficient and Guaranteed Data Transmission
IPv4 and IPv6 Protocols
Abundant Multicast Protocols
Static and Dynamic Routing
The hardware supports dual stack for high-speed switching, catering to the requirements of campus network transition from IPv4 protocol to IPv6 protocol, with significant improvement in address table capacity and network security.
Point-to-multipoint directional communication can avoid data redundancy on the network, realizing safe and efficient data transmission.
In simple campus scenarios, the switch can achieve easy configuration and high information security, while in large-scale interconnecting scenarios, the switch can realize auto-negotiated update of transmission paths to improve transmission quality.
Network Security Policies and Real-Time Monitoring, Delivering Enhanced Network Robustness
CPP
NFPP
Large amounts of data from different sources are handled by CPP first to prevent direct attacks on the CPU, ensuring CPU stability under high usage, and achieving significant improvement in the device's security performance.
NFPP detects and controls malicious data in real time to protect CPU from high load damage, guaranteeing device management and operation, and improving network security and stability.
Ruijie Unified Networking Central (RG-UNC) Visualized Management, Automated and Effortless Operations
RG-UNC, a unified visual management platform, supports real-time monitoring of key devices and links, fine-grained alarms, centralized configuration backup and recovery, network-wide management, plug-and-play, and rapid deployment, enhancing O&M efficiency.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Sabit Servis Portları | 48 x 10/100/1000BAST-T ports; 4 x 1GE/10GE SFP+ ports |
|---|---|
| Modül Yuvası | 1 x expansion module slot; 2 x power module slots |
| Genişleme Modülü | M5000X-4XS2CQ; Note: The V1.X switch needs to be upgraded to version 12.5(4)B0701 or later to support the expansion module. |
| Güç Modülü | RG-PA150IB-F; RG-PD150IB-F |
| Fan Modülü | Desteklenmiyor |
| Sabit Yönetim Portu | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| USB | 1 x USB 2.0 port |
| Sistem Paket İletim Hızı | 586 Mpps |
|---|---|
| Sistem Anahtarlama Kapasitesi | 787 Gbps |
| İşlemci (CPU) | Dual-core CPU, each core with the clock speed of 1.2 GHz |
| Gerçek Zamanlı Saat (RTC) | Destekleniyor |
| BootROM | 16 MB (2 flash chips for 1+1 boot redundancy) |
| Flash Bellek | 4 GB eMMC |
| Bellek | 1 GB |
| Switch Tampon Belleği | 4 MB |
| Güç Kaynağı | 2 x pluggable power modules |
|---|---|
| Güç Girişi | RG-PA150IB-F (AC input):; Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz; Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; Maximum input current: 3 A; RG-PD150IB-F (DC input):; Rated input voltage: –48 V DC to –60 V DC; Maximum input voltage: –36 V DC to –75 V DC; Maximum input current: 5 A |
| Maks. Çıkış Gücü | RG-PA150IB-F: 150 W; RG-PD150IB-F: 150 W |
| Maks. Güç Tüketimi | 70 W (excluding expansion modules); 95 W (including expansion modules) |
| Cihaz Boyutları (G x D x Y) | 440 mm x 340 mm x 44 mm (17.32 in. x 13.39 in. x 1.73 in.) |
|---|---|
| Kutu Boyutları (G x D x Y) | 593 mm x 497 mm x 192 mm (23.35 in. x 19.57 in. x 7.56 in.) |
| Kabin Yüksekliği | 1 RU |
| Cihaz Ağırlığı | 4.5 kg (9.92 lbs) |
| Kutulu Ağırlık | 6.30 kg (13.89 lbs) |
| Sıcaklık | Operating temperature:; 0°C to 45°C (32°F to 113°F), V1.X without expansion modules or V2.X; 0ºC to 40ºC (32°F to 104°F), V1.X with expansion modules; Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At an altitude between 1,800 m ( 5,905.51 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum temperature decreases by 1°C (1.8°F). |
|---|---|
| Nem | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| Rakım | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.); Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) |
| MTBF | 939,840 hours (about 110 years) |
| Fan | 2 x fixed fan modules |
| Isı Dağılımı | Fan cooling, left-to-right airflow |
| Gürültü Seviyesi | 45°C (113°F): 57.9 dB |
| Güç Modülü Yedekliliği | 1+1 redundancy |
| Fan Yedekliliği | Desteklenmiyor |
| Güç Modülü Sıcak Takas | Destekleniyor |
| USB hot swapping | Destekleniyor |
| Cable hot swapping | Destekleniyor |
| Güç Kaynağı İzleme | Monitoring of the power supply model and status; Power supply failure alarming |
| Fan İzleme | Fan speed adjustment: 3 levels; Fan failure alarming |
| Sıcaklık İzleme | Temperature monitoring, over-temperature alarming |
| ESD Koruması | ESD contact/air discharge: 6 kV/8 kV; ESD susceptibility contact/air discharge: 8 kV/15 kV |
| Aşırı Gerilim Koruması | MGMT port: 4 kV; Service port: 10 kV; Power port: common mode 6 kV, differential mode 6 kV |
| Güvenlik Standardı | IEC 62368-1 |
|---|---|
| EMC Standardı | EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 |
| Maks. VSU Üye Sayısı | 8 |
|---|---|
| VSU bandwidth | 260 Gbps |
| Maximum number of SVIs | 1,000 |
| Maks. MAC Adres Kaydı | 64,000 |
| Maks. ARP Kaydı | 24,000 |
| Maximum number of ND entries | 12,000 |
| Maks. IPv4 Unicast Rota | 24,000 (shared with IPv6 routes) |
| Maks. IPv6 Unicast Rota | 14,000 (shared with IPv4 routes) |
| Maximum number of IPv4 multicast routes | 4,000 (3,000 in mmu-enhance mode) |
| Maximum number of IPv6 multicast routes | 2,000 (1,500 in mmu-enhance mode) |
| Maximum number of IGMP groups | 4,000 (3,000 in mmu-enhance mode) |
| Maximum number of MLD groups | 2,000 (1,500 in mmu-enhance mode) |
| Maximum number of VRF instances | 512 |
| Maximum number of ACEs | In: 75,000 Out:3,750 |
| Ethernet Anahtarlama | Jumbo frame (maximum length: 9,216 bytes); IEEE 802.1Q (supporting 4K VLANs); Voice VLAN; Super-VLAN and private VLAN; MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment; GVRP; Basic QinQ and selective QinQ; STP, RSTP, and MSTP; ERPS (G.8032); LLDP/LLDP-MED; LACP (IEEE 802.3ad) |
|---|---|
| IP Servisleri | ARP; DHCP client, DHCP relay, and DHCP server; DHCP snooping; DNS; DHCPv6 client, DHCPv6 server, and DHCPv6 relay; DHCPv6 snooping; Neighbor Discovery (ND) and ND snooping; IPV6 addressing, ICMPv6, Stateless Address Auto-configuration (SLAAC), and path MTU discovery |
| IP Yönlendirme | Static routing; RIP and RIPng; OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6; BGP4 and BGP4+; ECMP; IPv4 and IPv6 VRF; IPv4 and IPv6 PBR |
| Multicast | IGMP v1/v2/v3 and IGMP proxy; IGMP v1/v2/v3 snooping; IGMP filtering and IGMP fast leave; PIM-DM, PIM-SM, and PIM-SSM; MSDP; MLD snooping v1/v2; PIM-SMv6 and PIM-SSM v6 |
| MPLS | MPLS L3VPN |
| ACL ve QoS | Standard IP ACLs; Extended IP ACLs; Extended MAC ACLs; Time-based ACLs; Expert-level ACLs; ACL80; IPv6 ACL; ACL redirection; Port traffic identification; Port traffic rate limiting; Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ; Congestion avoidance: tail drop, RED, and WRED; 802.1p/DSCP/ToS traffic classification; Eight priority queues per port |
| Güvenlik | AAA; RADIUS and TACAS+; Port-based and MAC address-based 802.1X authentication; Web authentication; HTTPS; SSHv1 and SSHv2; Global IP-MAC binding; Port isolation and port security; IP source guard; SAVI; CPP and NFPP; Strict and loose RPF; uRPF ignoring default routes; 3-tuple binding (IP address, MAC address, and port); 3-tuple binding (IPv6 address, MAC address, and port); Filtering of unauthorized MAC addresses; MAC address bypass (MAB) authentication; Portal authentication and Portal 2.0 aut |
| Güvenilirlik | REUP, RLDP, and DLDP; IPv4 VRRP v2/v3 and IPv6 VRRP; GR for RIP, OSPF, BGP, and other routing protocols; BFD; Link tracing, fault notification, and remote loopback based on 802.3ah (EFM); 1+1 power module redundancy; Hot swapping of power modules and cables; 3-level fan speed adjustment; Fan fault alarm |
| Cihaz Sanallaştırma | VSU |
| Ağ Yönetimi ve Bakım | SPAN, RSPAN, and ERSPAN; sFlow; NTP and SNTP; FTP and TFTP; SNMP v1/v2c/v3; RMON (1, 2, 3, 9); SSHv1 and SSHv2; Syslog; NETCONF; CWMP (TR-069); gRPC; CLI (Telnet/Console), SNMP over IPv6, IPv6 MIB support for SNMP, SSHv6, Telnet v6, FTP/TFTP v6, DNS v6, NTP for IPv6, and Traceroute v6 |
| PoE | RG-S5760C-48GT4XS-HP-E:; IEEE 802.3af and 802.3at, uninterruptible power supply upon hot start, and port priority |
| VXLAN | With VXLAN, a Layer 2 logical network can be built based on a Layer 3 network through software upgrade. |
| Sistem Anahtarlama Kapasitesi | 787 Gbps |
|---|---|
| Sistem Paket İletim Hızı | 586 Mpps |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F), without expansion modules 0ºC to 40ºC (32°F to 104°F), with expansion modules |
| Warranty duration | 3 years |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-S5760C-48GT4XS-X hakkında kısa yanıtlar.
RG-S5760C-48GT4XS-X kaç portlu?
RG-S5760C-48GT4XS-X fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-S5760C-48GT4XS-X için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch kategorisinden
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S5760C-X serisi
Ruijie RG-S5760C-24GT8XS-X 24 Port Gigabit 8×10G SFP+ L3 Yönetilebilir Switch
Ruijie RG-S5760C-24SFP/8GT8XS-X 24 Port Gigabit SFP 8×10G SFP+ L3 Yönetilebilir Switch
Ruijie RG-S5760C-48GT4XS-HP-X 48 Port Gigabit PoE+ 4×10G SFP+ L3 Yönetilebilir Switch