Ruijie RG-N18010-X 8 Slot Modüler Veri Merkezi Switch
RG-N18010-XRuijie RG-N18010-X bir yönetilebilir switch'tir. Öne çıkan özellikleri: diverse port types and flexible access capability with 200ge, 100ge, 40ge, and 10ge line cards, cross-device link aggregation (de-stacking/m-lag/vsu), implementing device-level redundancy, flexible networking, and high reliability, hardware-level reliability, ensuring service continuity and network stability, vxlan tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling.
- Port hızı
- 10G uplink
- PoE
- PoE yok
- Diverse port types and flexible access capability with 200GE, 100GE, 40GE, and 10GE line cards
- Cross-device link aggregation (de-stacking/M-LAG/VSU), implementing device-level redundancy, flexible networking, and high reliability
- Hardware-level reliability, ensuring service continuity and network stability
- VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
- Midplane-free design, improving data transmission efficiency
- Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient
Genel bakış
Ruijie RG-N18010-X özellikleri ve kullanım alanları.
Fit for the core or aggregation node of a legacy data center or core node of a cloud data center, enabling smooth evolution to 400GE in future
100GE Data Center Modular Core Switch RG-N18010-X
Up to 384 x 100GE ports, 288 x 40GE ports, and 1152 x 10GE ports, for line-rate forwarding Ultra-large distributed buffer design, 200 ms buffering per port, and 24 GB buffer per card, ensuring zero packet loss upon traffic burst.
Line cards:
- M18000X-48DC-CE: CE series line card with 48 x 200GE QSFP56 ports
- M18000X-48CQ-CE: CE series line card with 48 x 100GE QSFP28 ports
- M18000X-36CQ-CE: CE series line card with 36 x 100GE QSFP28 ports
- M18000X-36QXS-CB: CB series line card with 36 x 40GE QSFP+ ports
- M18000X-48XS2CQ-CB: CB series line card with 48 x 10GE SFP+ ports and 2 x 100GE QSFP28 ports
Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability
De-stacking
M-LAG
VSU
De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.
M-LAG technology implements load sharing between links and improves link reliability. The independent control plane supports independent device upgrade, realizing service upgrade within seconds and consistent user experience.
VSU technology can virtualize multiple physical devices into one logical device, simplifying network configuration and architecture, eliminating loops, and improving reliability.
Midplane-free Design, Improving Data Transmission Efficiency
Midplane-free design
Clos architecture
Eliminates the need for a midplane between the line card and the switch fabric module. This enables direct data transmission from the line card to the switch fabric module, reducing distance and minimizing transmission loss. As a result, data transmission efficiency is significantly improved.
Separates the control plane from the forwarding plane, eliminating mutual interference and enhancing stability. 1:1 oversubscription and dynamic routing achieve link load balancing and non-blocking data forwarding.
VXLAN Tunneling Technology, Achieving Unlimited Data Transmission and Flexible Resource Allocation and Scheduling
VXLAN technology creates virtual tunnels on an IP network by building a virtual Layer 2 network, implementing cross-region and cross-DC data migration, and flexible resource allocation and scheduling. The switch supports EVPN VXLAN to enhance the number of tenants, meeting requirements of identification and isolation between different networks on a large scale.
Hardware-level Reliability, Ensuring Service Continuity and Network Stability
N+1 redundancy of switch fabric modules: Secures nonstop traffic transmission through loading sharing and redundancy.
M+N redundancy of power modules: Achieves failover within seconds and delivers uninterrupted service upon power replacement, providing link-level protection.
M+N redundancy of fan modules: Supports smart speed regulation for efficient heat dissipation.
1+1 redundancy of supervisor modules: Guarantees service continuity.
Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient
The switch enabled with Telemetry/gRPC/sFlow/SPAN provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Boyutlar (G x D x Y) | 442 mm x 961 mm x 534 mm (17.40 in. x 37.83 in. x 21.02 in.), without the cable management bracket;; 442 mm x 1017 mm x 534 mm (17.40 in. x 40.04 in. x 21.02 in.), with the cable management bracket. |
|---|---|
| Kabin Yüksekliği | 12 RU |
| Cihaz Ağırlığı | 52 kg (114.640 lbs., a chassis with three fan modules) |
| Anahtarlama Kapasitesi | 153.6 Tbps |
| Paket İletim Hızı | 34,560 Mpps |
| Modül Yuvaları | 2 x supervisor module slots; 8 x line card slots; 6 x switch fabric module slots; 8 x power module slots; 3 x fan module slots |
| Güç Girişi | RG-PA2700I (AC input); Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90V AC to 290 V AC, 47 Hz to 63 Hz; Rated input current: 16 A; Power port type: C20; RG-PA2700I (HVDC input):; Rated input voltage: 240V: 192~288V DC; Maximum input voltage: 192V~350V DC; Note: When the switch is equipped with the high-voltage DC power supply, a PDU that supports high-voltage DC power supply must be used. To ensure safety, connect the external power supply to the power cord firs |
| Sıcaklık | Operating temperature: 0ºC to 40ºC (32ºF to 104ºF); Storage temperature: –40ºC to +70ºC (–40ºF to +158ºF); Note: At altitudes ranging from 3,000 m (9,842.52 ft.) to 5,000 m (16,404.20 ft.), the maximum temperature decreases by 6°C (10.8°F) for every 1,000 m (3280.84 ft.) increase in elevation. |
| Nem | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| Rakım | Operating altitude: ≤ 3,000 m (9,842.52 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.) |
| Soğutma | Air cooling, front-to-rear airflow (port-side air intake) |
| Cihaz Sanallaştırma | Virtual Switching Unit 3.0 |
|---|---|
| Data center features | VXLAN bridge; VXLAN gateway; BGP-EVPN VXLAN; VXLAN mapping; IPv6 VXLAN over IPv4; M-LAG |
| SDN | OpenFlow 1.3. |
| Traffic analysis | sFLOW; IPFIX; NetFlow |
| Katman 2 Özellikleri | Jumbo frame; IEEE 802.3ad (static link aggregation, LACP, cross-module link aggregation, M-LAG); IEEE 802.1Q; STP, RSTP, MSTP; GVRP; QinQ; LLDP; Static MAC addresses, address filtering, and limit on the number of MAC addresses |
| IPv4 features | Static routing, RIP, OSPF, IS-IS, and BGP4; VRRP; ECMP; Policy-based routing |
| IPv6 features | Static routing, OSPFv3, BGP4+, IS-ISv6, and MLDv1/v2; VRRPv3; ECMP; Policy-based routing; Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6 |
| Multicast | IGMP v1/v2/v3; IGMP Snooping; IGMP Proxy; MLDv1, MLDv2; Multicast static routing; Fast leave |
| ACL | Standard, extended, and expert-level ACLs; Global ACLs; Ingress/Egress ACLs; IPv6 ACLs |
| QoS | Mapping of IEEE 802.1p, DSCP, and ToS priorities; Priority marking/remarking; Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR; Congestion avoidance mechanisms such as RED and WRED; Port-based rate limit |
| Güvenilirlik | Independent switch fabric modules and independent supervisor engines to implement thorough separation of the forwarding plane from the control plane; 1+1 redundancy for supervisor modules; N+1 redundancy for switch fabric modules; N+M redundancy for power modules and fan modules; Midplane-free design to avoid single point of failures; Hot swapping of components; Hot patching; BPDU guard/Loop guard/Root guard; ISSU; NSR; DLDP; FRR; Micro-segmentation security isolation; GR for OSPF/IS-IS/BGP; BFD |
| Güvenlik | Network Foundation Protection Policy (NFPP) and CPU protection policy (CPP) to prevent protocol packet attacks; Prevention against DDoS, ARP, and ICMP attacks; DAI, port security, IP source guard, and protected ports; uRPF; RADIUS and TACACS user login authentication, password security, hierarchical user management, and password protection; Source IP address restriction; Function of not sending unknown multicast packets to the CPU; Suppression of unknown multicast, unknown broadcast, and unknown |
| Yönetim | Console/AUX Modem/Telnet/SSH2.0 CLI configuration; FTP, TFTP, Xmodem, and SFTP; SNMP V1/V2c/V3; NETCONF; RMON; NTP clock; Fault alarm and auto-recovery; System operation logging; Traffic analysis; Zero-touch provisioning (ZTP); Reliable network service (RNS), which probes specific services provided by the peer device to monitor the service availability; Telemetry; Buffer status monitoring and traffic microburst identification; Port mirroring, traffic mirroring, and ERSPAN; Physical ports on all |
| Çalışma Sıcaklığı | 0ºC to 40ºC (32ºF to 104ºF) |
|---|---|
| Çalışma Nemi | 10% to 90% RH (non-condensing) |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-N18010-X hakkında kısa yanıtlar.
RG-N18010-X fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-N18010-X için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch kategorisinden
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-N18000-X serisi