Ziton ZX432-2P Kablosuz Dedektör Tabanı
ZX432-2PZiton ZX432-2P (Ziton Wireless Detectors ailesi), kablosuz dedektör tabanı ürünüdür. CPD, EN54-5, EN54-7 standart/onaylarına uygundur. Öne çıkan özellikleri: EN 54 uyumluluğu.
- Bağlantı
- Kablosuz
- Sertifika
- EN 54
- Sistem tipi
- Adresli
Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.
- Wireless optical heat head to work with ZR401-3 base & battery pack, polar white
- No external aerials
- Dual battery supply via base
- Full device status monitoring – power sources, head removal and device tamper
- Senses both smoke and heat
Teknik özellikler
Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
Genel 4 satır
| Status indication | Red alarm LED |
|---|---|
| Wireless frequency | 868 MHz |
| Uyumluluk | All ZP addressable systems via RLM |
| Adresleme Yöntemi | Unique address embedded |
Elektriksel 3 satır
| Power supply type | Batteries |
|---|---|
| Aküler | Batteries in base |
| Çalışma Gerilimi | 3 VDC |
Algılama 3 satır
| Algılama Prensibi | Smoke element - Photoelectric light scatter Heat element - Thermistor |
|---|---|
| Monitoring | Continuously self-checking |
| Kapsama Alanı | Smoke element - |
Fiziksel 5 satır
| Boyutlar | 106 x 75 mm (including base) (Ø x H) |
|---|---|
| Net Ağırlık | 350 g (including base & batteries) |
| Renk | Polar white |
| Montaj Tipi | Surface mount |
| Material (body) | Moulded ABS |
Çevresel 5 satır
| Çalışma Sıcaklığı | -10 to +60°C |
|---|---|
| Depolama Sıcaklığı | -20 to +70°C |
| Bağıl Nem | 10 to 95% noncondensing |
| Ortam | Indoor |
| IP Koruma Sınıfı | IP32 |
Sertifikalar ve Uyumluluk 2 satır
| Uyumluluk Belgeleri | CE, CPR, REACH, RoHS |
|---|---|
| Sertifikalar | CPD, EN54-5, EN54-7 |
Genel bakış
Ziton ZX432-2P kullanım alanları ve özellikleri.
Ziton ZX432-2P (Ziton Wireless Detectors ailesi), kablosuz dedektör tabanı ürünüdür. CPD, EN54-5, EN54-7 standart/onaylarına uygundur.
General
The ZX432-2P is a wireless, POLAR WHITE addressable multisensor head capable of operating in optical, temperature or multisensor, optical/heat modes.
Product works with ZR401-3
Fast response to a wide range of fires
Designed to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option, ZX432-2 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day, or used on a day night basis in premises where heat only is required whilst the building is occupied.
Detector control
The ZX432-2 detector is controlled from the main control panel via a wireless base and loop wired radio interface module allowing both wireless and hardwired devices to be seamlessly located and controlled from the same wiring loop. Every wireless device controlled through the radio loop module, is assigned its own IDENT address with which the main control panel communicates, providing the same system facilities as directly wired devices.
System operation
Temperature and smoke sensitivity may be set by a selection of switches located in the base of the ZX432-2. Calibration and self-testing are carried out automatically.
Removal or replacement of an incorrect sensing devices are identified by the system and details displayed at the main control panel. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.
For ease of removal, ZX432-2 detectors plug into the radio base by a simple twist and lock action.
Certification
The ZX432-2 temperature response meets the requirements of European Standard EN54 Part 5 (settable to class A or class B), with smoke sensitivity complying with EN54 Part 7. The ZR432-2 is approved to EN54:5, EN54:7 , and carries CPD certification.
Öne Çıkan Özellikler
- No external aerials
- Dual battery supply via base
- Full device status monitoring – power sources, head removal and device tamper
- Senses both smoke and heat
Nerelerde kullanılır?
Yangın algılama sisteminde giriş/çıkış kontrolü, loop izolasyonu veya kurulum aksesuarı olarak kullanılır.
Kurulum ve uyumluluk
Yangın algılama sistemleri; Binaların Yangından Korunması Hakkında Yönetmelik ve TS EN 54 standardına uygun olarak projelendirilmeli ve yetkili ekiplerce devreye alınmalıdır.
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
ZX432-2P hakkında kısa yanıtlar.
ZX432-2P kablosuz mu çalışır?
ZX432-2P EN 54 sertifikalı mı?
ZX432-2P fiyatı ne kadar?
Hızlı teklif
Formu doldurun, ZX432-2P için fiyat ve teslim süresini iletelim.
Yangın Modülü & Aksesuar
Ziton Ziton Wireless Detectors