  • 2 zones.Each zone can have maximum 32 conventional detectors. The total number of detectors and call points in a zone shall not exceed 32
  • Each zone can be programed work as fire alarm (default) or supervisory alarm mode
  • Each zone include 2 indicators, 1st indicator is bi-color( Red and Green), factory default to indicate fire condition. Red color on in case fire signal triggered; also can be programed to indicate supervisory condition.
  • 3x sounder outputs, output 1 can be setup 24V or N/O N/C, output 2 and 3 only work as 24V output
  • 1x Disable/supervisory relay ouput (N/O COM N/C)
  • 1 x Fault output (N/O COM N/C)
  • 1x Auxilary power output: output current 450mA in standby mode and Maximum 1000mA in alarm mode when the Alarm Output been set to a normally open/close contact type
  • Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output

Teknik özellikler

Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.

Teknik Özellikler 13 satır
Şebeke Beslemesi+10% 220/230VAC -15%, 50/60Hz
Standby Power7AH/24VDC
Maximum internal resistance of the batteries1
Bölge Sayısı2
Cihaz Kapasitesi32 detectors per zone
End of Line for zoneAEOL (a ctive end of line) or EOLR (0.5Watt/4.7k )
End of Line for othersEOLR (0.5Watt/4.7k ) Sounder output, Alarm output
KorumaIP30
StandartEN54-2 1997 + A1: 2006, EN 54-4 1997+A1: 2002+A2:2006
OnaylarLPCB
Çalışma Ortamı0°C ~ +40°C 95%, non condensing
Boyutlar430mm(W)x320mm(H)x98mm(D)
Ağırlık4.0kg
Sertifikalar 2 satır
StandartlarEN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006
SertifikalarLPCB Technic al Specification Primary Supply 220/230VAC + -11 50 %% , 50/60Hz Standby Power 7AH/24VDC Maximum internal resistance of the 1 batteries Zone Quantity 2 Device Capacity 32 detectors per zone End of Line for AEOL (a ctive end of line) or EOLR zone (0.5Watt/4.7k ) End of Line for EOLR (0.5Watt/4.7k ) others Sounder output, Alarm output Protection IP30 EN54-2 1997 + A1: 2006, Standard EN 54-4 1997+A1: 2002+A2:2006 Approval LPCB Operating 0°C ~ +40°C Environment 95%, non condensing Dimen

Genel bakış

GST GST108A kullanım alanları ve özellikleri.

GST GST108A, EN54 (CE) ürün gamında yer alan konvansiyonel yangın alarm paneli modelidir. Öne çıkan değerler: standart: EN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006.

GST GST108A Conventional Fire Alarm Control Panel

GST102A Conventional Fire Alarm Control Panel is designed in compliance with EN 54-2 1997 + A1: 2006 & EN 54-4 1997+A1: 2002+A2:2006 standard. It’s compatible with GST conventional detectors, manual call points and sounders. The panel is easy to install and operate. Control functions are enabled by a key switch. Programming functions are enabled by a key switch and an internal switch.

Özellikler

  • 2 zones.Each zone can have maximum 32 conventional detectors. The total number of detectors and call points in a zone shall not exceed 32
  • Each zone can be programed work as fire alarm (default) or supervisory alarm mode
  • Each zone include 2 indicators, 1st indicator is bi-color( Red and Green), factory default to indicate fire condition. Red color on in case fire signal triggered; also can be programed to indicate supervisory condition. Green color on in case superisory signal triggered. 2nd abmer indicator flashes when the zone is in fault condition(0.5:0.5).
  • 3x sounder outputs, output 1 can be setup 24V or N/O N/C, output 2 and 3 only work as 24V output
  • 1x Disable/supervisory relay ouput (N/O COM N/C)
  • 1 x Fault output (N/O COM N/C)
  • 1x Auxilary power output: output current 450mA in standby mode and Maximum 1000mA in alarm mode when the Alarm Output been set to a normally open/close contact type
  • Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output
  • D esigned with standby batteries and space provision for two sealed lead-acid batteries
  • Easy operation to enable/disable zones, sounder outputs and alarm output
  • Alarm Test function selectable with or without sounder notification
  • Output programmable for interlink between zones and sounder outputs, alert or evacuate tone, with or without delay

Sertifikalar ve Uyumluluk

  • Standards: EN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006
  • Certifications: LPCB Technic al Specification Primary Supply 220/230VAC + -11 50 %% , 50/60Hz Standby Power 7AH/24VDC Maximum internal resistance of the 1 batteries Zone Quantity 2 Device Capacity 32 detectors per zone End of Line for AEOL (a ctive end of line) or EOLR zone (0.5Watt/4.7k ) End of Line for EOLR (0.5Watt/4.7k ) others Sounder output, Alarm output Protection IP30 EN54-2 1997 + A1: 2006, Standard EN 54-4 1997+A1: 2002+A2:2006 Approval LPCB Operating 0°C ~ +40°C Environment 95%, non condensing Dimensions 430mm(W)x320mm(H)x98mm(D) Weight 4.0kg

Nerelerde kullanılır?

Binadaki dedektör, buton ve sirenleri yöneten yangın algılama sisteminin merkezidir; alarmın yerini gösterir, tahliye uyarısını başlatır ve diğer sistemlerle (asansör, havalandırma, kapılar) entegre çalışır.

Kurulum ve uyumluluk

Yangın algılama sistemleri; Binaların Yangından Korunması Hakkında Yönetmelik ve TS EN 54 standardına uygun olarak projelendirilmeli ve yetkili ekiplerce devreye alınmalıdır.

Tüm özellikler

  • 2 zones.Each zone can have maximum 32 conventional detectors. The total number of detectors and call points in a zone shall not exceed 32
  • Each zone can be programed work as fire alarm (default) or supervisory alarm mode
  • Each zone include 2 indicators, 1st indicator is bi-color( Red and Green), factory default to indicate fire condition. Red color on in case fire signal triggered; also can be programed to indicate supervisory condition.
  • 3x sounder outputs, output 1 can be setup 24V or N/O N/C, output 2 and 3 only work as 24V output
  • 1x Disable/supervisory relay ouput (N/O COM N/C)
  • 1 x Fault output (N/O COM N/C)
  • 1x Auxilary power output: output current 450mA in standby mode and Maximum 1000mA in alarm mode when the Alarm Output been set to a normally open/close contact type
  • Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output
  • D esigned with standby batteries and space provision for two sealed lead-acid batteries
  • Easy operation to enable/disable zones, sounder outputs and alarm output
  • Alarm Test function selectable with or without sounder notification
  • Output programmable for interlink between zones and sounder outputs, alert or evacuate tone, with or without delay

Dokümanlar

Veri sayfası ve kullanım kılavuzları.

Sık sorulanlar

GST108A hakkında kısa yanıtlar.

GST108A adresli mi, konvansiyonel mi?
GST108A konvansiyonel bir üründür; alarm bölge (zone) bazında gösterilir.
GST108A kaç bölge (zone) destekler?
GST108A 2 bölge desteğine sahiptir.
GST108A EN 54 sertifikalı mı?
Ürün dokümanlarında EN 54 standardına uygunluk belirtilmektedir. Proje teslimi için güncel sertifika belgesi talep edilebilir.
GST108A fiyatı ne kadar?
GST108A için fiyat; adet, proje kapsamı ve güncel kura göre değiştiğinden teklif usulüyle verilir. Ürünü teklif listenize ekleyerek veya telefon/WhatsApp hattımızdan ulaşarak aynı iş günü içinde fiyat ve stok bilgisi alabilirsiniz.

Hızlı teklif

Formu doldurun, GST108A için fiyat ve teslim süresini iletelim.

Benzer ürünler

Yangın Alarm Paneli

Tümü
Aynı seri

GST CE (EN54) Ürünleri